Schedule
Production Planning & Capacity
Finite capacity planning, workshop loading and bottleneck identification. Reflects all current edits.
Team Capacity (this week, hours)
| Team | Capacity | Allocated | Free | Load | Projects |
|---|---|---|---|---|---|
| Design | 320 | 280 | 40 | 88% | 4 |
| Procurement | 240 | 230 | 10 | 96% | 4 |
| Stores & Kitting | 160 | 120 | 40 | 75% | 3 |
| Steelwork | 400 | 380 | 20 | 95% | 3 |
| CNC | 320 | 240 | 80 | 75% | 2 |
| Copper Shop | 280 | 290 | -10 | 104% | 4 |
| Assembly | 640 | 560 | 80 | 88% | 4 |
| Wiring | 720 | 700 | 20 | 97% | 4 |
| Quality | 200 | 180 | 20 | 90% | 4 |
| Test/FAT | 160 | 90 | 70 | 56% | 2 |
Panel-Level Workshop Loading
Panel
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
SC-2401
MSB-01-INC-01
SC-2401
MSB-01-INC-02
SC-2401
MSB-01-BUS-01
SC-2401
MSB-01-OUT-01
SC-2401
MSB-01-OUT-02
SC-2401
MSB-01-OUT-03
SC-2401
MSB-01-OUT-04
SC-2401
MSB-01-OUT-05
SC-2401
MSB-01-OUT-06
SC-2401
MSB-01-OUT-07
SC-2401
MSB-01-OUT-08
SC-2401
DB-A-TPN-01
SC-2401
DB-A-TPN-02
SC-2401
DB-A-TPN-03
SC-2401
DB-A-TPN-04
SC-2401
DB-A-TPN-05
SC-2401
DB-A-TPN-06
SC-2401
DB-B-TPN-01
SC-2401
DB-B-TPN-02
SC-2401
DB-B-TPN-03
SC-2401
DB-B-TPN-04
SC-2401
DB-B-TPN-05
SC-2401
DB-B-TPN-06
SC-2402
PLC-Cab-PLC-01
SC-2402
PLC-Cab-PLC-02
SC-2402
PLC-Cab-PLC-03
SC-2402
PLC-Cab-PLC-04
SC-2402
PLC-Cab-MAR-01
complete in progress not startedShowing first 28 panels